PLD3600 Hospital Digital Imaging Radiography System Medical X-ray Machine Equipment

Customization: Available
Certification: CE, ISO13485
Scale: Large

Product Description

📋 Basic Info.
Model NO.PLD3600
Voltage220V
Frequency50Hz
Capacity≥40kVA
Power32kw
Inverter Frequency30kHz
SpecificationMax. Tube Current: 100mA
OriginChina
HS Code94029000
Production Capacity1000 Sets/Month
🔍 Product Overview

PLD3600 Hospital Digital Imaging Radiography System Medical X-ray Machine Equipment

Digital Radiography System
📦 Packing Details (4 wooden cases)
No. Packing Dimension(mm) NW(Kg) GW(Kg)
12290*1340*910410546
22360*800*550140240
31760*1085*915110132.5
4986*547*1077120146
🏥 Application

This machine is applied to take digital radiography on every part of human body, such as head, limbs, chest, limbus and abdomen and etc.

⚙️ Technical Specifications
Item Content Technical Parameter
Power Supply Voltage 220V 50Hz
Capacity ≥40kVA Internal resistor: ≤0.15Ω
Generator Power Output 32KW
Inverter Frequency 30 KHz
Photography Tube Voltage 40kV-150kV -
Tube Current 10mA-320mA -
Exposure time 1.0ms-6300ms -
X-ray Tube Tube Focus 1.2mm /0.6mm Large/Small Focus
Anode Speed 2800rpm Thermal capacity: 110KJ
Radiography Table Movement Longitudinal ≥900mm Transverse ≥220mm
Collimator Manual Multi-leaf -
🖥️ Flat Panel Detector
Vision size358mm(H)×430 mm(V)
Pixel Matrix2560(H)×3072(V)
Pixel Pitch139 μm
Imaging timeless than 10s
A / D transform14 bit
Standard Configuration
No. Item Model Quantity
1Control ConsoleKZT101 unit
2HF HV generatorFSQ30R1 set
3X-ray tube assemblyLQ161 unit
4CollimatorXSQ301 unit
5Radiography TableSYC201 unit
6Bucky StandXPJ301 unit
7Flat Panel DetectorPLD-1417S1 set
8Image acquisition WorkstationDRA401 set
🌟 Key Features
  • 220V low power supply, convenient installment.
  • High cost-effective FPD DR, suitable for primary hospital to realize digitalization.
  • Floating table with bucky stand meets photographic requirements for standing and lying positions.
  • Portable flat panel detector for wheel chair or stretcher patients.
  • Toshiba 14" *17" OEM digital flat Panel detector for high-definition images.
  • Domestic high power compact high frequency X-ray generator and inverter.
  • KV and MA digital closed-loop control and real-time microprocessor accuracy.
  • Multiple automatic protection features and fault tips for safety.
  • Vehicle-mounted model option for mobile medical examination and emergency use.
📸 Detailed Images
Product Detail 1
Product Detail 2
Product Detail 3
Frequently Asked Questions
Q1: What is the power requirement for the PLD3600 X-ray machine? A1: The system operates on a standard 220V low power supply with a frequency of 50Hz, making it convenient for installation in most medical facilities.
Q2: How fast can I see the images after exposure? A2: The flat panel detector provides high-definition digital imaging with an acquisition time of less than 10 seconds.
Q3: Is the table movable for different patient positions? A3: Yes, the system features a floating table with electromagnetic locks, allowing for accurate and flexible positioning for both standing and lying patients.
Q4: Can this system be used for emergency or mobile applications? A4: Yes, it is designed with a compact generator and can be configured as a vehicle-mounted model for mobile medical examinations and emergency rescue use.
Q5: What parts of the body can be scanned with this radiography system? A5: The PLD3600 is versatile and can be used for digital radiography of the head, limbs, chest, limbus, abdomen, and more.
Q6: What type of detector does the system use? A6: It uses a world-leading Toshiba 14"x17" OEM digital flat panel detector to ensure high limiting resolution and 14-bit image depth.

Related Products