Sy-T021 High Quality 150L-500L Autoclave Sterilizer Lab Sterilization Equipment

Customization: Available
Certification: CE
Timer: 0-60 Min

Product Description

SY-T021 High Quality 150L-500L Autoclave Sterilizer

Autoclave Sterilizer SY-T021

Basic Specifications

Model NO.
SY-T021
Product Name
Lab Autoclave
Working Temperature
134 Degree
Working Pressure
0.22MPa
Sterilizing Volume
150/200/280/400/500L
Warranty
1 Year
After-Sale Service
Online Technical Support
Production Capacity
100 Set/Month

Technical Parameters

Model SY-T021-150YDA SY-T021-200YDA SY-T021-280YDA SY-T021-400YDA SY-T021-500YDA
Chamber Volume 150L φ480×850mm 200L φ515×1000mm 280L φ600×1000mm 400L Φ700×1100mm 500L Φ700×1300mm
Working Pressure 0.22MPa
Working Temp 134°C (Adjustment: 40°C - 134°C)
Sterilization Time 0-60 min
Drying Time 0-60 min
Heat Average ≤± 2°C
Power (380V 50Hz) 9KW 9KW 12KW 18KW 18KW
G.W/N.W (KG) 320/240 350/260 465/365 530/520 580/470

Key Features

1
Automatic sterilization course controlled by system, making it extremely easy to operate.
2
Equipped with a dedicated drying function, suitable for medical dressing drying.
3
Integrated over-temperature and over-pressure automatic protection devices for safety.
4
Safety door interlock: Mechanism cannot be operated until pressure is below 0.027MPa.
5
Automatic safety valve opens if inner pressure exceeds 0.24MPa to exhaust steam to the tank.
6
Automatic water-off protection and alarm system when the machine lacks water.

Product Gallery

Autoclave specifications
Full structure

Frequently Asked Questions

What is the maximum sterilization temperature for the SY-T021?
The maximum working temperature is 134°C, which is ideal for rapid and effective sterilization of laboratory equipment and medical dressings.
Does this autoclave include a drying function?
Yes, the SY-T021 features a dedicated drying function, making it suitable for drying various sterilized materials after the cycle is complete.
What safety mechanisms are built into the device?
It includes over-temperature and over-pressure auto-protection, a safety valve that opens at 0.24MPa, and a door interlock system that prevents opening until pressure drops to 0.027MPa.
What are the available chamber volumes for this model?
We offer a range of sizes to suit different needs: 150L, 200L, 280L, 400L, and 500L.
What happens if the water level is too low?
The machine is equipped with an automatic water-off protection system. If it lacks water, the power will be cut off automatically and an alarm will sound.
Is the sterilization process manual or automatic?
The entire sterilization course is automatically controlled, ensuring consistency and ease of operation for the user.

Related Products